  • 1606-XLP30E 1.3A, NEC2P1
  • 1606-XLP50E 2.1A, NEC2P1 
  • 1606-XLP50EZ 2.1A, NEC2P1, Removable Screw Terminals 
  • 1606-XLP72E 3A, NEC2P1 
  • 1606-XLP100E 4.2A, 1P 
  • 1606-XL60D 2.5A, NEC2P1 
  • 1606-XLDNET4 4A, NEC2P1, Current Limited to 4A 
  • 1606-XL120D 5A, 1P 
  • 1606-XL240E 10A, 1P 
  • 1606-XL120E-3 5A, 3 Phase 
  • 1606-XL240E-3 10A, 3 Phase 
  • 1606-XL60DR 2.5A, NEC2P1, Redundant (DD) 
  • 1606-XL120DR 5A, 1P, Redundant (DD) 
  • 1606-XL240DR 10A, 1P, Redundant (DD) 
  • 1606-XLDNET8 8A, 1P, DD, Current Limited to 8A                                

Power Supply Special Modules

  • 1606-XLPRED 10A Dual Decoupling Module 
  • 1606-XLRED40 40A Single Decoupling Module 
  • 1606-XLRED20-30 30A Dual Decoupling Module 
  • 1606-XLBUFFER 20A, 200ms, DC Buffer Module 

    Note: NEC2P1 = NEC Class 2, 1P
    DD = Decoupling Diode
    1P = Single Phase                                                                                

Features Include

  • DIN-Rail Mountable 
  • 24VDC Single Output
  • Single Phase Input Voltage: 85 - 264VAC
  • 3 Phase Input Voltage: 340 - 576VAC (2 Phase Operation permitted)
  • Decoupling Diodes included on all Redundant Power Supplies
  • Global Agency Approvals; UL Listed, CE
  • Outputs fully protected against Open, Short Circuit and Overload
  • 1606-XLDNET4 is current limited to 4A to not exceed the capabilities of the thin cable
  • 1606-XLDNET8 is current limited to 8A to not exceed the capabilities of the thick cable

Odva conformant large

An ODVA Declaration of Conformity has been issued for the product(s) described on this page.

This Declaration confirms that the product(s) passed conformance and related testing at an ODVA vendor-independent Test Service Provider.

Doc icon   Download the Declaration of Conformity

DOC Number: 10793 Year: 2009

Email icon   Request EDS File

Explicit Peer-to-Peer
I/O Peer-to-Peer
Other Settings
Quick Connect
Master Scanner
Faulted Node Recovery
Configuration Consistency Value
Baud Rates
I/O Slave Messaging
Bit Strobe
Change of State
Device Configuration
Hardware Switches
Parameter Object
Custom Software
CIP Safety Node
Vendor Specific
Safety Discrete I/O
bookmark Bookmark This Page

Member Gallery Listing From

Ra  pms hires

Available ODVA Technology from this company

EtherNet/IP ID: 1
DeviceNet ID: 1
ControlNet ID: 1