$ Electronic Data Sheet for NE1A-SCPU02-EIP [File] DescText ="NE1A-SCPU02-EIP EDS File"; CreateDate = 03-22-2008; CreateTime = 11:00:00; ModDate = 03-22-2008; ModTime = 11:00:00; Revision = 1.1; EDSFileCRC = 0xC748559C; $ EDS File CRC [Device] VendCode = 47; $ Vendor Code ProdType = 768; $ Product Type ProdCode = 1412; $ Product Code MajRev = 1; $ Major Rev MinRev = 1; $ Minor Rev VendName = "Omron Corporation"; ProdTypeStr = "Safety Network Controller"; $ Device type string ProdName = "NE1A-SCPU02-EIP"; Catalog = ""; 47_DNetScannerPlugIn = "NE1AENIPDeviceV1.ScannerPlugIn"; [Port] Port1 = DeviceNet, "DeviceNet I/F", , 2; Port2 = TCP, "EtherNet/IP port", "20 F5 24 01", 4; [Device Classification] Class1 = DeviceNet; Class2 = EtherNetIP; Class3 = Safety; [Capacity] TSpec1 = TxRx, 2, 6000; TSpec2 = TxRx, 1446, 6000; [Connection Manager] MaxSafetyConnections = 4; MaxSafetyInputCnxns = 4; MaxSafetyOutputCnxns = 4; [47_DNetSafetyScanner] StandardMaster = 0; StandardSlave = 2; SCID_Type = 1; SafetyTargetPathType = 2; MaxConnections = 32; MaxInputConnections = 32; MaxOutputConnections = 32; StandardInputTable = "Standard Input Table", 2, 256; SafetyInputTable = "Safety Input Table", 2, 512; StandardOutputTable = "Standard Output Table", 2, 256; SafetyOutputTable = "Safety output Table", 2, 512; ErrorHistoryType = 1; ConnectionMonitorType = 1; OffLink = 1; Logic = true; [47_SafetyMonitor] LogicEditorTool = "LogicEditorTool.LogicEditor"; TaskFormat = 1; Import = 1; ImportCode = 1403,1404,1405,1407,1408,1411; LogicDelay = 1, 20, 12, 1; MaxSafetyInputInstance = 40; MaxSafetyOutputInstance = 8; MaxDualChSafetyInputInstance = 20; MaxDualChSafetyOutputInstance = 4; MaxStandardOutputInstance = 8; MaxSafetyOutputTerminalName = 32; MaxSafetyInputTerminalName = 32; MaxOutputTerminalName = 32; LatchOutputErrorTime = 0, 65530, 1000, 10; LatchInputErrorTime = 0, 65530, 1000, 10; OutputChMode = 0, $Default 0, "Not Used", 1, "Safety", 2, "Safety Pulse Test"; OutputDualChMode = 1, $Default 0, "Single Channel", 1, "Dual Channel"; TestOutputMode = 0, $Default 0, "Not Used", 1, "Standard Output", 2, "Pulse Test Output", 4, "Muting Lamp Output"; LogicFaultAction = 0, $Default 0, "Clear off", 1, "Hold last data"; InputChMode = 0, $Default 0, "Not Used", 1, "Test pulse from test out", 2, "Used as safety input", 3, "Used as standard input"; TestSource = 0, $Default 0, "Not Used", 1, "Test Output0", 2, "Test Output1", 3, "Test Output2", 4, "Test Output3"; TestSource2 = 0, $Default 0, "Not Used", 5, "Test Output4", 6, "Test Output5", 7, "Test Output6", 8, "Test Output7"; OnDelay = 0, 126, 0, 1; OffDelay = 0, 126, 0, 1; InputDualChMode = 0, $Default 0, "Single Channel", 1, "Dual Channel Equivalent", 2, "Dual Channel Complementary"; DiscrepancyTime = 0, 65530, 0, 10; AutoExecution = 0, $Default 0, "Normal Mode", 1, "Automatic Execution Mode"; DNetCommunication = 0, $Default 0, "Enable (Normal Mode)", 1, "Disable (Stand Alone Mode)"; MaintenanceMode = 0, $Default 0, "Time", 1, "Count"; ConnectionErrorMode = 0, $Default 0, "Auto Recovery", 1, "Stop Error Connections", 2, "Stop All Connections"; LocalInputStatusBit1 = "Local Input Status #0", "Local Input Status #1", "Local Input Status #2", "Local Input Status #3", "Local Input Status #4", "Local Input Status #5", "Local Input Status #6", "Local Input Status #7"; LocalInputStatusBit2 = "Local Input Status #8", "Local Input Status #9", "Local Input Status #10", "Local Input Status #11", "Local Input Status #12", "Local Input Status #13", "Local Input Status #14", "Local Input Status #15"; LocalInputStatusBit3 = "Local Input Status #16", "Local Input Status #17", "Local Input Status #18", "Local Input Status #19", "Local Input Status #20", "Local Input Status #21", "Local Input Status #22", "Local Input Status #23"; LocalInputStatusBit4 = "Local Input Status #24", "Local Input Status #25", "Local Input Status #26", "Local Input Status #27", "Local Input Status #28", "Local Input Status #29", "Local Input Status #30", "Local Input Status #31"; LocalInputStatusBit5 = "Local Input Status #32", "Local Input Status #33", "Local Input Status #34", "Local Input Status #35", "Local Input Status #36", "Local Input Status #37", "Local Input Status #38", "Local Input Status #39"; LocalOutputStatusBit = "Local Output Status #0", "Local Output Status #1", "Local Output Status #2", "Local Output Status #3", "Local Output Status #4", "Local Output Status #5", "Local Output Status #6", "Local Output Status #7"; TestOutputStatusBit1 = "Test Output Status #0", "Test Output Status #1", "Test Output Status #2", "Test Output Status #3", "", "", "", "Muting Lamp Status #3"; TestOutputStatusBit2 = "Test Output Status #4", "Test Output Status #5", "Test Output Status #6", "Test Output Status #7", "", "", "", "Muting Lamp Status #7"; GeneralStatusBit = "Local Input Power Supply Status", "Local Output Power Supply Status", "Standard I/O Error Status", "Standard I/O Communication Status", "Safety I/O Error Status (Safety Master/Safety Slave)", "Safety I/O Communication Status (Safety Master)", "Run Status", "Normal Status"; LocalInputMonitorBit1 = "Local Input Monitor #0", "Local Input Monitor #1", "Local Input Monitor #2", "Local Input Monitor #3", "Local Input Monitor #4", "Local Input Monitor #5", "Local Input Monitor #6", "Local Input Monitor #7"; LocalInputMonitorBit2 = "Local Input Monitor #8", "Local Input Monitor #9", "Local Input Monitor #10", "Local Input Monitor #11", "Local Input Monitor #12", "Local Input Monitor #13", "Local Input Monitor #14", "Local Input Monitor #15"; LocalInputMonitorBit3 = "Local Input Monitor #16", "Local Input Monitor #17", "Local Input Monitor #18", "Local Input Monitor #19", "Local Input Monitor #20", "Local Input Monitor #21", "Local Input Monitor #22", "Local Input Monitor #23"; LocalInputMonitorBit4 = "Local Input Monitor #24", "Local Input Monitor #25", "Local Input Monitor #26", "Local Input Monitor #27", "Local Input Monitor #28", "Local Input Monitor #29", "Local Input Monitor #30", "Local Input Monitor #31"; LocalInputMonitorBit5 = "Local Input Monitor #32", "Local Input Monitor #33", "Local Input Monitor #34", "Local Input Monitor #35", "Local Input Monitor #36", "Local Input Monitor #37", "Local Input Monitor #38", "Local Input Monitor #39"; LocalOutputMonitorBit = "Local Output Monitor #0", "Local Output Monitor #1", "Local Output Monitor #2", "Local Output Monitor #3", "Local Output Monitor #4", "Local Output Monitor #5", "Local Output Monitor #6", "Local Output Monitor #7"; [47_UnitName] UnitNameParam = 32, "20 01 24 01 30 64"; [47_StatusMonitor] ParamEnumCount=0x00030005; $ High word is Monitor Param Count, Low word is Monitor Enum. MonitorParam1 = 8, "21 07 03 24 FF 30 67", "Test Output%d Value", 1, "21 07 03 24 FF 30 78", "Test Output%d Status", 2, "21 07 03 24 FF 30 76", "Reason for Test Output%d Alarm", 3; MonitorParam2 = 40, "20 3D 24 FF 30 03", "Safety Input%d Value", 1, "20 3D 24 FF 30 04", "Safety Input%d Status", 2, "20 3D 24 FF 30 07", "Safety Input%d Logical Value", 1, "20 3D 24 FF 30 6E", "Reason for Safety Input%d Alarm", 4; MonitorParam3 = 8, "20 3B 24 FF 30 03", "Safety Output%d Value", 1, "20 3B 24 FF 30 04", "Safety Output%d Monitor Value", 1, "20 3B 24 FF 30 05", "Safety Output%d Status", 2, "20 3B 24 FF 30 6E", "Reason for Safety Output%d Alarm", 5; MonitorEnum1 = 0, "OFF", 1, "ON"; MonitorEnum2 = 0, "Alarm", 1, "OK"; MonitorEnum3 = 0, "No alarm", 1, "Configuration invalid", 2, "Overload detected", 3, "Cross circuit detected", 5, "Stuck-at-high detected", 6, "Under current is detected using muting lamp"; MonitorEnum4 = 0, "No alarm", 1, "Configuration invalid", 2, "External connected device failure", 3, "Internal circuit failure", 4, "Discrepancy error", 5, "Failure of the associated dual channel input"; MonitorEnum5 = 0, "No alarm", 1, "Configuration invalid", 2, "Over current detected", 3, "Short circuit to low", 4, "Stuck at high", 5, "Failure of the associated dual channel output", 6, "Internal Relay relevant Circuit Error (Replace Module)", 7, "Relay Failure (Replace Relay)", 8, "Dual channel violation", 9, "Cross connection detected"; [47_ExceptionDetail] ExceptionCount=0x00070000; $ High word is Manufacturer Exception Count, Low word is Device Exception. Manufacturer1= "Bus Off", "Duplicate MAC ID", "Transmission Timeout", "Network PS Voltage Low", , "Switch Setting Mismatch", "Invalid Configuration", "System Failure"; Manufacturer2= "Safety I/O Connection Timeout", "Safety I/O Connection Establishment Failure", "Invalid Slave Device", "Nonexistent Slave Device", "Standard I/O Connection Timeout", , , ; Manufacturer3= "External Test Signal Failure at Safety Input", "Internal Input Failure at Safety Input", "Discrepancy Error at Safety Input", , "Overload Detected at Test Output", , "Stuck-at-high Detected at Test Output", "Under Current Detected Using Muting Lamp"; Manufacturer4= "Over Current Detected at Safety Output", "Short Circuit Detected at Safety Output", "Stuck-at-high Detected at Safety Output", "Dual Channel Violation at Safety Output", , , "Cross Connection Detected at Safety Output", ; Manufacturer5= "Input PS Voltage Low", "Output PS Voltage Low", , , , , , "Total ON Time or Contact Operation Counter Exceeded Threshold at Any Point"; Manufacturer6= "EM Transmission Error(Device Offline)", "EM Transmission Error(Duplicate MAC ID)", "EM Transmission Error(Destination Device Absence)", "EM Transmission Error(Destination Buffer Full)", "EM Transmission Error(Command Length Error)", "EM Transmission Error(Invalid Header)", "EM Transmission Error(Message ID Error)", "EM Transmission Error(Response Timeout)"; Manufacturer7= "EM Transmission Error(New Request Received)", "Received Error Response(UEM)", "Function Block Status Error", "Relevant Safety I/O Communication Stopped", "All Safety I/O Communication Stopped", "Ethernet Slave I/O Connection Timeout", , ; [47_Wizard] Param = 40,8,8,1,2; [47_ExceptionBitDetail] ExceptionInput = 40,"20 3D 24 FF 30 6E"; ExceptionOutput = 8,"20 3B 24 FF 30 6E"; ExceptionTestOut = 8,"21 07 03 24 FF 30 76"; ExceptionTestOutEnum = 0, "No alarm", 1, "Configuration invalid", 2, "Overload detected", 3, "Cross circuit detected", 5, "Stuck-at-high detected", 6, "Under current is detected using muting lamp"; ExceptionInputEnum = 0, "No alarm", 1, "Configuration invalid", 2, "External test signal failure", 3, "Internal input failure", 4, "Discrepancy error", 5, "Failure of the associated dual channel input"; ExceptionOutputEnum = 0, "No alarm", 1, "Configuration invalid", 2, "Over current detected", 3, "Short circuit to low", 4, "Stuck at high", 5, "Failure of the associated dual channel output", 6, "Internal Relay relevant Circuit Error (Replace Module)", 7, "Relay Failure (Replace Relay)", 8, "Dual channel violation", 9, "Cross connection detected"; [47_FunctionBlock_section] Number = 23; StartupTime = 5; InterruptDelayTimeBasicSoftware = 268; SwitchTime = 3; MiniScannerDelayMultiplier = 485; MaxNumber = 254; FunctionBlock1 = $ "NOT" 1, $ Revision "NOT", $ FunctionBlock Name 1, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 0, $ sfb_ID 1, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0840, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 1, $ Max Input number (input 1,2 and reset input) 1, $ Max Output number (includes "/Fault Present") 1, $ Min Input number 1, $ Min Output number 1, $ Default Input number (Reset, Input1) 1, $ Default Output number (Output1) "FBICON\\NOT.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\NOT.html", $ Help file for specified FunctionBlock 14, $ Min. execution time (ms): this value is assumption. 14, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 0, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ---------------------------------------------------------------------------------- Input_Info1_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input1"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info1_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Output1"; $ Input Name. $======================================================================================= FunctionBlock2 = $ "AND" 1, $ Revision "AND", $ FunctionBlock Name 1, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 0, $ sfb_ID 2, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0840, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 8, $ Max Input number (input 1,2 and reset input) 1, $ Max Output number (includes "/Fault Present") 1, $ Min Input number 1, $ Min Output number 2, $ Default Input number (Reset, Input1) 1, $ Default Output number (Output1) "FBICON\\AND.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\AND.html", $ Help file for specified FunctionBlock 17, $ Min. execution time (ms): this value is assumption. 46, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 0, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ---------------------------------------------------------------------------------- Input_Info2_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input1"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info2_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input2"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info2_3 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input3"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info2_4 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input4"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info2_5 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input5"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info2_6 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input6"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info2_7 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input7"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info2_8 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input8"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info2_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Output1"; $ Input Name. $======================================================================================= FunctionBlock3 = $ "OR" 1, $ Revision "OR", $ FunctionBlock Name 1, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 0, $ sfb_ID 3, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0840, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 8, $ Max Input number (input 1,2 and reset input) 1, $ Max Output number (includes "/Fault Present") 1, $ Min Input number 1, $ Min Output number 2, $ Default Input number (Reset, Input1) 1, $ Default Output number (Output1) "FBICON\\OR.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\OR.html", $ Help file for specified FunctionBlock 17, $ Min. execution time (ms): this value is assumption. 44, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 0, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ---------------------------------------------------------------------------------- Input_Info3_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input1"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info3_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input2"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info3_3 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input3"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info3_4 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input4"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info3_5 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input5"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info3_6 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input6"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info3_7 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input7"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info3_8 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input8"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info3_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Output1"; $ Input Name. $======================================================================================= FunctionBlock4 = $ "EXOR" 1, $ Revision "EXOR", $ FunctionBlock Name 1, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 0, $ sfb_ID 4, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0840, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 2, $ Max Input number (input 1,2 and reset input) 1, $ Max Output number (includes "/Fault Present") 2, $ Min Input number 1, $ Min Output number 2, $ Default Input number (Reset, Input1) 1, $ Default Output number (Output1) "FBICON\\EXOR.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\EXOR.html", $ Help file for specified FunctionBlock 19, $ Min. execution time (ms): this value is assumption. 19, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 0, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ---------------------------------------------------------------------------------- Input_Info4_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input1"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info4_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input2"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info4_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Output1"; $ Input Name. $======================================================================================= FunctionBlock5 = $ "EXNOR" 1, $ Revision "EXNOR", $ FunctionBlock Name 1, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 0, $ sfb_ID 5, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0840, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 2, $ Max Input number (input 1,2 and reset input) 1, $ Max Output number (includes "/Fault Present") 2, $ Min Input number 1, $ Min Output number 2, $ Default Input number (Reset, Input1) 1, $ Default Output number (Output1) "FBICON\\EXNOR.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\EXNOR.html", $ Help file for specified FunctionBlock 19, $ Min. execution time (ms): this value is assumption. 19, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 0, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ---------------------------------------------------------------------------------- Input_Info5_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input1"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info5_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input2"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info5_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Output1"; $ Input Name. $======================================================================================= FunctionBlock6 = $ "Routing" 1, $ Revision "Routing", $ FunctionBlock Name 5, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 0, $ sfb_ID 6, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0840, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 1, $ Max Input number 8, $ Max Output number 1, $ Min Input number 1, $ Min Output number 1, $ Default Input number 1, $ Default Output number "FBICON\\routing.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\Routing.html", $ Help file for specified FunctionBlock 38, $ Min. execution time (ms): this value is assumption. 38, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 0, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ---------------------------------------------------------------------------------- Input_Info6_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input1"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info6_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Output1"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info6_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Output2"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info6_3 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Output3"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info6_4 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Output4"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info6_5 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Output5"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info6_6 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Output6"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info6_7 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Output7"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info6_8 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Output8"; $ Input Name. $======================================================================================= FunctionBlock7 = $ "Restart" 1, $ Revision "Restart", $ FunctionBlock Name 4, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 1, $ sfb_ID 0, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0841, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 8, $ Max Input number 3, $ Max Output number 2, $ Min Input number 3, $ Min Output number 2, $ Default Input number 3, $ Default Output number "FBICON\\restart.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\Restart.html", $ Help file for specified FunctionBlock 75, $ Min. execution time (ms): this value is assumption. 75, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 0, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ------------------------------------------------------------------------------- Param7_1= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Restart/Reset", $ name "", $ unit "", $ Help string 0,1,0, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 0,1,0; $ offset/ usebit/ ConfigNumber EnumPar7_1= 1,"Restart"; $ ------------------------------------------------------------------------------- Param7_2= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Restart Signal", $ name "", $ unit "", $ Help string 0,2,0, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 2,2,0; $ offset/ usebit/ ConfigNumber EnumPar7_2= 0,"Low-High-Low", $ EnumString 1,"Rising Edge"; $ ------------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Input_Info7_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\LHL.ico", $ Icon file "Restart", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 1, $ Value (In this case, it means "Auto Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\RE.ico", $ Icon file "Restart", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 2, $ Value (In this case, it means "H-L-H") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\RE.ico", $ Icon file "Restart"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info7_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\input.ico", $ Icon file "Monitored Input", $ Input Name. $------------------------------------------------------------ 0, $ Reference (which "Param-section" is related with) 1, $ Value (In this case, it means "Auto Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\input.ico", $ Icon file "Monitored Input"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info7_3 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x001, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\option.ico", $ Icon file "Optional Input1"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info7_4 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x001, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\option.ico", $ Icon file "Optional Input2"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info7_5 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x001, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\option.ico", $ Icon file "Optional Input3"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info7_6 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x001, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\option.ico", $ Icon file "Optional Input4"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info7_7 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x001, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\option.ico", $ Icon file "Optional Input5"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info7_8 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x001, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\option.ico", $ Icon file "Optional Input6"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info7_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\output.ico", $ Icon file "Output Enable"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info7_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x009, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\output.ico", $ Icon file "Static Release"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info7_3 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x009, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\ressim.ico", $ Icon file "Restart Required Indication"; $ Input Name. $------------------------------------------------------------ $======================================================================================= FunctionBlock8 = $ "Reset" 1, $ Revision "Reset", $ FunctionBlock Name 4, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 1, $ sfb_ID 0, $ sfun_ID 1, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0841, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 8, $ Max Input number 3, $ Max Output number 2, $ Min Input number 3, $ Min Output number 2, $ Default Input number 3, $ Default Output number "FBICON\\reset.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\Reset.html", $ Help file for specified FunctionBlock 75, $ Min. execution time (ms): this value is assumption. 75, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 0, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ------------------------------------------------------------------------------- Param8_1= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Restart/Reset", $ name "", $ unit "", $ Help string 0,1,0, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 0,1,0; $ offset/ usebit/ ConfigNumber EnumPar8_1= 1,"Reset"; $ ------------------------------------------------------------------------------- Param8_2= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Reset Signal", $ name "", $ unit "", $ Help string 0,2,0, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 2,2,0; $ offset/ usebit/ ConfigNumber EnumPar8_2= 0,"Low-High-Low", $ EnumString 1,"Rising Edge"; $ ------------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Input_Info8_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\LHL.ico", $ Icon file "Reset", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 1, $ Value (In this case, it means "Auto Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\RE.ico", $ Icon file "Reset", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 2, $ Value (In this case, it means "H-L-H") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\RE.ico", $ Icon file "Reset"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info8_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\input.ico", $ Icon file "Monitored Input", $ Input Name. $------------------------------------------------------------ 0, $ Reference (which "Param-section" is related with) 1, $ Value (In this case, it means "Auto Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\input.ico", $ Icon file "Monitored Input"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info8_3 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x001, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\option.ico", $ Icon file "Optional Input1"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info8_4 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x001, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\option.ico", $ Icon file "Optional Input2"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info8_5 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x001, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\option.ico", $ Icon file "Optional Input3"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info8_6 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x001, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\option.ico", $ Icon file "Optional Input4"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info8_7 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x001, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\option.ico", $ Icon file "Optional Input5"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info8_8 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x001, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\option.ico", $ Icon file "Optional Input6"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info8_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\output.ico", $ Icon file "Output Enable"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info8_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x009, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\output.ico", $ Icon file "Static Release"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info8_3 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x009, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\ressim.ico", $ Icon file "Reset Required Indication"; $ Input Name. $------------------------------------------------------------ $ ==================================================================================== FunctionBlock9 = $ "E-STOP" 1, $ Revision "E-STOP", $ FunctionBlock Name 3, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 2, $ sfb_ID 0, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0841, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 2, $ Max Input number (input 1,2 and reset input) 2, $ Max Output number (includes "/Fault Present") 2, $ Min Input number 1, $ Min Output number 2, $ Default Input number (Reset, Input1) 1, $ Default Output number (Output1) "FBICON\\E-STOP.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\E-STOP.html", $ Help file for specified FunctionBlock 48, $ Min. execution time (ms): this value is assumption. 48, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 1, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------- Param9_1= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Reset Condition", $ name "", $ unit "", $ Help string 1,1,1, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 0,1,0; $ offset/ usebit/ ConfigNumber EnumPar9_1= 1,"Auto Reset"; Param9_2= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Input Type", $ name "", $ unit "", $ Help string 0,2,1, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 4,2,0; $ offset/ usebit/ ConfigNumber EnumPar9_2= 0,"Single Channel", 1,"Dual Channel Equivalent", 2,"Dual Channel Complementary"; $ ------------------------------------------------------------------------------- Param9_3= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_SETTABLE_PATH) 0xC7, $ data type=UINT 2, $ data size=2byte "Discrepancy Time", $ name "ms", $ unit "", $ Help string 0,0xBB8,3, $ min/ max/ default 10,1,1,1, $ mult/ div /base/ offset scaling 10,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places 0,16,1; $ offset/ usebit/ ConfigNumber $ ---------------------------------------------------------------------------------- Input_Info9_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x04A, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\NC.ico", $ Icon file "Input1 (NC)", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x0A2, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input1 (NC)", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x092, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input1 (NC)"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info9_2 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input2 (NC)", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x052, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input2 (NC)", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x062, $ Descriptor "FBICON\\NO.ico", $ Icon file "Input2 (NO)"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info9_3_1 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "", $ Icon file "Reset", $ Input Name. $------------------------------------------------------------ 1, $ Reference (which "Param-section" is related with) 1, $ Value 0x004, $ Descriptor "", $ Icon file "Auto Reset"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info9_3 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "FBICON\\LHL.ico", $ Icon file "Reset(L-H-L)", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x004, $ Descriptor "FBICON\\HLH.ico", $ Icon file "Reset(H-L-H)", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x004, $ Descriptor "FBICON\\RE.ico", $ Icon file "Reset: Rising Edge"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info9_1 = $ this field defines the Output1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\output.ico", $ Icon file "Output Enable"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info9_2 = $ this field defines the Output1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "FBICON\\error.ico", $ Icon file "Discrepancy Error"; $ Input Name. $ ==================================================================================== FunctionBlock10 = $ "EDM" 1, $ Revision "EDM", $ FunctionBlock Name 3, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 3, $ sfb_ID 0, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0841, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 3, $ Max Input number (input 1,2 and reset input) 3, $ Max Output number (includes "/Fault Present") 3, $ Min Input number 3, $ Min Output number 3, $ Default Input number (Reset, Input1) 3, $ Default Output number (Output1) "FBICON\\edm.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\EDM.html", $ Help file for specified FunctionBlock 50, $ Min. execution time (ms): this value is assumption. 50, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 1, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ------------------------------------------------------------------------------- Param10_1= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Reset Condition", $ name "", $ unit "", $ Help string 1,1,1, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 0,1,0; $ offset/ usebit/ ConfigNumber EnumPar10_1= 1,"Auto Reset"; $ ------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------- Param10_2= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_SETTABLE_PATH) 0xC7, $ data type=UINT 2, $ data size=2byte "Max. Feedback Time", $ name "ms", $ unit "", $ Help string 10,100,30, $ min/ max/ default 10,1,1,0, $ mult/ div /base/ offset scaling 10,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places 0,16,1; $ offset/ usebit/ ConfigNumber $ ---------------------------------------------------------------------------------------------- Input_Info10_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\fb.ico", $ Icon file. "EDM Feed Back", $ Input Name. $------------------------------------------------------------ 1, $ Reference (which "Param-section" is related with) 1, $ Value 0x00A, $ Descriptor "FBICON\\fb.ico", $ Icon file. "EDM Feed Back"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info10_2_1 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "", $ Icon file "Reset", $ Input Name. $------------------------------------------------------------ 0, $ Reference (which "Param-section" is related with) 1, $ Value 0x004, $ Descriptor "", $ Icon file "Auto Reset"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info10_2 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "FBICON\\LHL.ico", $ Icon file "Reset: Low-High-Low Signal", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x004, $ Descriptor "FBICON\\HLH.ico", $ Icon file "Reset: High-Low-High Signal", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x004, $ Descriptor "FBICON\\RE.ico", $ Icon file "Reset: Rising Edge"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info10_3 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\input.ico", $ Icon file. "Monitored Input", $ Input Name. $------------------------------------------------------------ 1, $ Reference (which "Param-section" is related with) 1, $ Value 0x00A, $ Descriptor "FBICON\\input.ico", $ Icon file. "Monitored Input"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info10_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x009, $ Descriptor "FBICON\\error.ico", $ Icon file. "EDM error"; $ Input Name. $------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------------ Output_Info10_2 = $ this field defines the Input1 configuration. $ ------------------------------------------------------------------------------------ 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\output.ico", $ Icon file. "Output1"; $ Input Name. $----------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------------ Output_Info10_3 = $ this field defines the Input1 configuration. $ ------------------------------------------------------------------------------------ 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00C, $ Descriptor "FBICON\\output.ico", $ Icon file. "Output2"; $ Input Name. $----------------------------------------------------------------------------------- $ ==================================================================================== FunctionBlock11 = $ "On-Delay Timer" 1, $ Revision "On-Delay Timer", $ FunctionBlock Name 2, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 4, $ sfb_ID 0, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0841, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 1, $ Max Input number (input 1,2 and reset input) 1, $ Max Output number (includes "/Fault Present") 1, $ Min Input number 1, $ Min Output number 1, $ Default Input number (Reset, Input1) 1, $ Default Output number (Output1) "FBICON\\ondelay.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\OnDelayTimer.html", $ Help file for specified FunctionBlock 23, $ Min. execution time (ms): this value is assumption. 23, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 1, $ Display Attribute 0, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ $ ------------------------------------------------------------------------------- Param11_1= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_SETTABLE_PATH) 0xC7, $ data type=UINT 2, $ data size=2byte "Delay Time", $ name "ms", $ unit "", $ Help string 0,0x7530,0, $ min/ max/ default (0~300s (=300,000ms = 0x7530ms) 10,1,1,0, $ mult/ div /base/ offset scaling 10,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places 0,16,1; $ offset/ usebit/ ConfigNumber $ ---------------------------------------------------------------------------------- Input_Info11_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\input.ico", $ Icon file. "Input"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info11_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\output.ico", $ Icon file. "Output Enable"; $ Input Name. $------------------------------------------------------------ $ ==================================================================================== FunctionBlock12 = $ "Off-Delay Timer" 1, $ Revision "Off-Delay Timer", $ FunctionBlock Name 2, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 5, $ sfb_ID 0, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0840, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 1, $ Max Input number (input 1,2 and reset input) 1, $ Max Output number (includes "/Fault Present") 1, $ Min Input number 1, $ Min Output number 1, $ Default Input number (Reset, Input1) 1, $ Default Output number (Output1) "FBICON\\offdelay.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\OffDelayTimer.html", $ Help file for specified FunctionBlock 23, $ Min. execution time (ms): this value is assumption. 23, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 1, $ Display Attribute 0, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ------------------------------------------------------------------------------- Param12_1= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_SETTABLE_PATH) 0xC7, $ data type=UINT 2, $ data size=2byte "Delay Time", $ name "ms", $ unit "", $ Help string 0,0x7530,0, $ min/ max/ default (0~300s (=300,000ms = 0x7530ms) 10,1,1,0, $ mult/ div /base/ offset scaling 10,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places 0,16,1; $ offset/ usebit/ ConfigNumber $ ---------------------------------------------------------------------------------- Input_Info12_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\input.ico", $ Icon file. "Input"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info12_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\output.ico", $ Icon file. "Output Enable"; $ Input Name. $------------------------------------------------------------ $ ==================================================================================== FunctionBlock13 = $ "User Mode Switch" 1, $ Revision "User Mode Switch", $ FunctionBlock Name 3, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 6, $ sfb_ID 0, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0841, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 8, $ Max Input number (input 1,2 and reset input) 8, $ Max Output number (includes "/Fault Present") 2, $ Min Input number 2, $ Min Output number 2, $ Default Input number (Reset, Input1) 2, $ Default Output number (Output1) "FBICON\\ums.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\UserModeSwitch.html", $ Help file for specified FunctionBlock 77, $ Min. execution time (ms): this value is assumption. 77, $ Worst execution time (ms): this value is assumption. 1, $ Syncro 0, $ Display Attribute 1, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ---------------------------------------------------------------------------------- Input_Info13_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Input1"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info13_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00B, $ Descriptor "", $ Icon file. "Input2"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info13_3 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "", $ Icon file. "Input3"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info13_4 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "", $ Icon file. "Input4"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info13_5 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "", $ Icon file. "Input5"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info13_6 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "", $ Icon file. "Input6"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info13_7 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "", $ Icon file. "Input7"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info13_8 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "", $ Icon file. "Input8"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info13_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Output1"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info13_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Output2"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info13_3 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Output3"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info13_4 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Output4"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info13_5 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Output5"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info13_6 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Output6"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info13_7 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Output7"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info13_8 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Output8"; $ Input Name. $------------------------------------------------------------ $ ==================================================================================== FunctionBlock14 = $ "Safety Gate Monitoring" 1, $ Revision "Safety Gate Monitoring", $ FunctionBlock Name 3, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 7, $ sfb_ID 0, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0841, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 6, $ Max Input number (input 1,2 and reset input) 6, $ Max Output number (includes "/Fault Present") 6, $ Min Input number 1, $ Min Output number 6, $ Default Input number (Reset, Input1) 1, $ Default Output number (Output1) "FBICON\\sgm.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\SafetyGateMonitoring.html", $ Help file for specified FunctionBlock 117, $ Min. execution time (ms): this value is assumption. 117, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 1, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ------------------------------------------------------------------------------- Param14_1= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Reset Condition", $ name "", $ unit "", $ Help string 1,1,1, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 0,1,0; $ offset/ usebit/ ConfigNumber EnumPar14_1= 1,"Auto Reset"; $ ------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------- Param14_2= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Input Type", $ name "", $ unit "", $ Help string 0,4,1, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 4,3,0; $ offset/ usebit/ ConfigNumber EnumPar14_2= 0,"Single Channel", 1,"DualChannel Equivalent(1pair)", 2,"DualChannel Complementary(1pair)", 3,"DualChannel Equivalent(2pairs)", 4,"DualChannel Complementary(2pairs)"; $ ------------------------------------------------------------------------------- Param14_3= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Function Test", $ name "", $ unit "", $ Help string 0,1,0, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 7,1,0; $ offset/ usebit/ ConfigNumber EnumPar14_3= 0,"no Function Test", 1,"Function Test Required"; $ ------------------------------------------------------------------------------- Param14_4= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte $ name "Discrepancy Time (pair1)", "ms", $ unit "", $ Help string 0,0xBB8,3, $ min/ max/ default 10,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places 0,16,1; $ offset/ usebit/ ConfigNumber $ ------------------------------------------------------------------------------- Param14_5= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte $ name "Discrepancy Time (pair2)", "ms", $ unit "", $ Help string 0,0xBB8,3, $ min/ max/ default 10,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places 0,16,2; $ offset/ usebit/ ConfigNumber $ ------------------------------------------------------------------------------- Param14_6= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte $ name "Syncronization Time", "ms", $ unit "", $ Help string 0,0xBB8,30, $ min/ max/ default 10,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places 0,16,3; $ offset/ usebit/ ConfigNumber $ ------------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Input_Info14_1 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value 0x04A, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input1 (pair1-NC)", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x0A2, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input1 (pair1-NC)", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x092, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input1 (pair1-NC)", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 3, $ Value 0x0A2, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input1 (pair1-NC)", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 4, $ Value 0x092, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input1 (pair1-NC)"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info14_2 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "", $ Icon file "", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x52, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input2 (pair1-NC)", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x62, $ Descriptor "FBICON\\NO.ico", $ Icon file "Input2 (pair1-NO)", $ Input Name $----------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 3, $ Value 0x52, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input2 (pair1-NC)", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 4, $ Value 0x62, $ Descriptor "FBICON\\NO.ico", $ Icon file "Input2 (pair1-NO)"; $ Input Name $----------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Input_Info14_3 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "", $ Icon file "", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x004, $ Descriptor "", $ Icon file "", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x004, $ Descriptor "", $ Icon file "", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 3, $ Value 0x112, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input3 (pair2-NC)", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 4, $ Value 0x122, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input3 (pair2-NC)"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info14_4 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "", $ Icon file "", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x004, $ Descriptor "", $ Icon file "", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x004, $ Descriptor "", $ Icon file "", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 3, $ Value 0x0E2, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input4 (pair2-NC)", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 4, $ Value 0x0D2, $ Descriptor "FBICON\\NO.ico", $ Icon file. "Input4 (pair2-NO)"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info14_5_1 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "", $ Icon file "Reset", $ Input Name. $------------------------------------------------------------ 1, $ Reference (which "Param-section" is related with) 1, $ Value 0x004, $ Descriptor "", $ Icon file "Auto Reset"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info14_5 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "FBICON\\LHL.ico", $ Icon file "Reset: Low-High-Low Signal", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x004, $ Descriptor "FBICON\\HLH.ico", $ Icon file "Reset: High-Low-High Signal", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x004, $ Descriptor "FBICON\\RE.ico", $ Icon file "Reset: Rising Edge"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info14_6 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 3, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "", $ Icon file "No FunctionTest", $ Input Name. $------------------------------------------------------------------------------------------- 3, $ Reference (which "Param-section" is related with) 1, $ Value 0x001, $ Descriptor "FBICON\\testin.ico", $ Icon file "FunctionTest signal"; $ Input Name $------------------------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Output_Info14_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\output.ico", $ Icon file. "Output Enable"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info14_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "FBICON\\error.ico", $ Icon file. "Discrepancy Error(Pair1)"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info14_3 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "FBICON\\error.ico", $ Icon file. "Discrepancy Error(Pair2)"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info14_4 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "FBICON\\testout.ico", $ Icon file. "Function Test Required"; $ Input Name. $------------------------------------------------------------ $ ------------------------------------------------------------------------------------ Output_Info14_5 = $ this field defines the Input1 configuration. $ ------------------------------------------------------------------------------------ 0, $ Reference 0, $ Value 0x001, $ Descriptor "FBICON\\error.ico", $ Icon file. "Synchronization Error"; $ Input Name. $------------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Output_Info14_6 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "FBICON\\error.ico", $ Icon file. "Function Test Error"; $ Input Name. $------------------------------------------------------------ $ ==================================================================================== FunctionBlock15 = $ "Light Curtain Monitoring" 1, $ Revision "Light Curtain Monitoring", $ FunctionBlock Name 3, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 2, $ sfb_ID 0, $ sfun_ID 1, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0841, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 2, $ Max Input number (input 1,2 and reset input) 2, $ Max Output number (includes "/Fault Present") 2, $ Min Input number 1, $ Min Output number 2, $ Default Input number (Reset, Input1) 1, $ Default Output number (Output1) "FBICON\\lc.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\LightCurtainMonitoring.html", $ Help file for specified FunctionBlock 57, $ Min. execution time (ms): this value is assumption. 57, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 1, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ------------------------------------------------------------------------------- Param15_1= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Reset Condition", $ name "", $ unit "", $ Help string 1,1,1, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 0,1,0; $ offset/ usebit/ ConfigNumber EnumPar15_1= 1,"Auto Reset"; $ ------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------- Param15_2= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Input Type", $ name "", $ unit "", $ Help string 1,2,1, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 4,2,0; $ offset/ usebit/ ConfigNumber EnumPar15_2= 1,"Dual Channel Equivalent", 2,"Dual Channel Complementary"; $ ------------------------------------------------------------------------------- Param15_3= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte $ name "Discrepancy Time", "ms", $ unit "", $ Help string 0,0xBB8,3, $ min/ max/ default 10,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places 0,16,1; $ offset/ usebit/ ConfigNumber $ ---------------------------------------------------------------------------------- Input_Info15_1 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value 0x0A2, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input1 (NC)", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x0A2, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input1 (NC)", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x092, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input1 (NC)"; $ Input Name $ ---------------------------------------------------------------------------------- Input_Info15_2 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value 0x52, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input2 (NC)", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x52, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input2 (NC)", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x62, $ Descriptor "FBICON\\NO.ico", $ Icon file "Input2 (NO)"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info15_1 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\output.ico", $ Icon file "Output Enable"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info15_2 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "FBICON\\error.ico", $ Icon file "DiscrepancyError", $ Input Name. $------------------------------------------------------------ 1, $ Reference (which "Param-section" is related with) 1, $ Value 0x001, $ Descriptor "FBICON\\error.ico", $ Icon file "DiscrepancyError"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info15_3 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "FBICON\\ressim.ico", $ Icon file "Reset Light Curtain"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info15_4 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "FBICON\\testout.ico", $ Icon file "Test Simulation Signal"; $ Input Name. $------------------------------------------------------------ $ ====================================================================================== FunctionBlock16 = $ "Two Hand Controller" 1, $ Revision "Two Hand Controller", $ FunctionBlock Name 3, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 9, $ sfb_ID 0, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0841, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 4, $ Max Input number (input 1,2 and reset input) 3, $ Max Output number (includes "/Fault Present") 4, $ Min Input number 1, $ Min Output number 4, $ Default Input number (Reset, Input1) 1, $ Default Output number (Output1) "FBICON\\thc.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\TwoHandControl.html", $ Help file for specified FunctionBlock 120, $ Min. execution time (ms): this value is assumption. 120, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 1, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ------------------------------------------------------------------------------------ Param16_1= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Reset Condition", $ name "", $ unit "", $ Help string 1,1,1, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 0,1,0; $ offset/ usebit/ ConfigNumber EnumPar16_1= 1,"Auto Reset"; $ ------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------- Param16_2= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte $ name "Discrepancy Time (pair1)", "ms", $ unit "", $ Help string 0,50,3, $ min/ max/ default 10,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places 0,16,1; $ offset/ usebit/ ConfigNumber $ ------------------------------------------------------------------------------- Param16_3= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte $ name "Discrepancy Time (pair2)", "ms", $ unit "", $ Help string 0,50,3, $ min/ max/ default 10,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places 0,16,2; $ offset/ usebit/ ConfigNumber $ ---------------------------------------------------------------------------------- Input_Info16_1 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 0, $ Value 0x092, $ Descriptor "FBICON\\NO.ico", $ Icon file "Input1 (Pair1-NO)", $ Input Name. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 1, $ Value 0x092, $ Descriptor "FBICON\\NO.ico", $ Icon file "Input1 (Pair1-NO)"; $ Input Name. $ ---------------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Input_Info16_2 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 0, $ Value 0x62, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input2 (Pair1-NC)", $ Input Name. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 1, $ Value 0x62, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input2 (Pair1-NC)"; $ Input Name. $ ---------------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Input_Info16_3 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 0, $ Value 0x112, $ Descriptor "FBICON\\NO.ico", $ Icon file "Input3 (Pair2-NO)", $ Input Name. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 1, $ Value 0x112, $ Descriptor "FBICON\\NO.ico", $ Icon file "Input3 (Pair2-NO)"; $ Input Name. $ ---------------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Input_Info16_4 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 0, $ Value 0x0D2, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input4 (Pair2-NC)", $ Input Name. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 1, $ Value 0x0D2, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input4 (Pair2-NC)"; $ Input Name. $ ---------------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Output_Info16_1 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x000A, $ Descriptor "FBICON\\output.ico", $ Icon file "Output Enable"; $ Input Name. $ ---------------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Output_Info16_2 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 0, $ Value 0x0001, $ Descriptor "FBICON\\error.ico", $ Icon file "Discrepancy Error (Pair1)", $ Input Name. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 0, $ Value 0x0001, $ Descriptor "FBICON\\error.ico", $ Icon file "Discrepancy Error (Pair1)"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info16_3 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 0, $ Value 0x0001, $ Descriptor "FBICON\\error.ico", $ Icon file "Discrepancy Error (Pair2)", $ Input Name. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 0, $ Value 0x0001, $ Descriptor "FBICON\\error.ico", $ Icon file "Discrepancy Error (Pair2)"; $ Input Name. $============================================================================================ FunctionBlock17 = $ "Comparator" 1, $ Revision "Comparator", $ FunctionBlock Name 1, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 0, $ sfb_ID 7, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0841, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 8, $ Max Input number (input 1,2 and reset input) 1, $ Max Output number (includes "/Fault Present") 1, $ Min Input number 1, $ Min Output number 1, $ Default Input number (Reset, Input1) 1, $ Default Output number (Output1) "FBICON\\Comparator.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\Comparator.htm", $ Help file for specified FunctionBlock 14, $ Min. execution time (ms): this value is assumption. 34, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 0, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ---------------------------------------------------------------------------------- Input_Info17_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input1"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info17_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input2"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info17_3 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input3"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info17_4 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input4"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info17_5 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input5"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info17_6 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input6"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info17_7 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input7"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info17_8 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Input8"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info17_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "", $ Icon file "Output Enable"; $ Input Name. $ ------------------------------------------------------------------------------- Param17_1= 0, $ shall Equal 0 , $ path size "", $ path 0x0001, $ descriptor(SUPPORT_SETTABLE_PATH) 0xC7, $ data type=UINT 1, $ data size=2byte "Comparison Data", $ name "-", $ unit "", $ Help string 0,0xFF,1, $ min/ max/ default (0~300s (=300,000ms = 0x7530ms) 1,1,1,0, $ mult/ div /base/ offset scaling 1,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 0,16,1; $ offset/ usebit/ ConfigNumber $ ==================================================================================== FunctionBlock18 = $ "Multi Connector" 1, $ Revision "Multi Connector", $ FunctionBlock Name 5, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 0, $ sfb_ID 8, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0841, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 8, $ Max Input number (input 1,2 and reset input) 8, $ Max Output number (includes "/Fault Present") 1, $ Min Input number 1, $ Min Output number 1, $ Default Input number (Reset, Input1) 1, $ Default Output number (Output1) "FBICON\\MultiConnector.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\MultiConnector.htm", $ Help file for specified FunctionBlock 77, $ Min. execution time (ms): this value is assumption. 77, $ Worst execution time (ms): this value is assumption. 1, $ Syncro 0, $ Display Attribute 0, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ---------------------------------------------------------------------------------- Input_Info18_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Input1"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info18_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00B, $ Descriptor "", $ Icon file. "Input2"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info18_3 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "", $ Icon file. "Input3"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info18_4 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "", $ Icon file. "Input4"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info18_5 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "", $ Icon file. "Input5"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info18_6 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "", $ Icon file. "Input6"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info18_7 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "", $ Icon file. "Input7"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info18_8 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "", $ Icon file. "Input8"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info18_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Output1"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info18_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Output2"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info18_3 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Output3"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info18_4 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Output4"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info18_5 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Output5"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info18_6 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Output6"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info18_7 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Output7"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info18_8 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "", $ Icon file. "Output8"; $ Input Name. $------------------------------------------------------------ $ ==================================================================================== FunctionBlock19 = $ "Counter" 1, $ Revision "Counter", $ FunctionBlock Name 2, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 10, $ sfb_ID 0, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0841, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 2, $ Max Input number (input 1,2 and reset input) 1, $ Max Output number (includes "/Fault Present") 2, $ Min Input number 1, $ Min Output number 2, $ Default Input number (Reset, Input1) 1, $ Default Output number (Output1) "FBICON\\Counter.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\Counter.htm", $ Help file for specified FunctionBlock 37, $ Min. execution time (ms): this value is assumption. 37, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 0, $ Use FaultPresent (0: not use/ 1: use) 1; $ Monitor FunctionBlock Internal Data $ ------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------- Param19_1= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Reset Condition", $ name "", $ unit "", $ Help string 0,1,1, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 0,1,0; $ offset/ usebit/ ConfigNumber EnumPar19_1= 0,"Auto Reset", 1,"Manual Reset"; Param19_2= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Count type", $ name "", $ unit "", $ Help string 0,1,0, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 2,1,0; $ offset/ usebit/ ConfigNumber EnumPar19_2= 0,"Down counter", 1,"Up counter"; Param19_3= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_SETTABLE_PATH) 0xC7, $ data type=UINT 2, $ data size=2byte "Counter", $ name "count", $ unit "", $ Help string 1,0xFFFF,1, $ min/ max/ default 1,1,1,1, $ mult/ div /base/ offset scaling 1,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 0,16,1; $ offset/ usebit/ ConfigNumber $ ---------------------------------------------------------------------------------- Input_Info19_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\input.ico", $ Icon file "Input", $ Input Name. 1, $ Reference (which "Param-section" is related with) $------------------------------------------------------------ 1, $ Value (In this case, it means "Reset") 0x00A, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\input.ico", $ Icon file "Input"; $ Input Name. $ ---------------------------------------------------------------------------------- Input_Info19_2 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "FBICON\\LHL.ico", $ Icon file "Reset(L-H-L)", $ Input Name. $------------------------------------------------------------ 0, $ Reference (which "Param-section" is related with) 1, $ Value 0x00A, $ Descriptor "FBICON\\RE.ico", $ Icon file "Reset"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info19_2_1 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "", $ Icon file "Auto Reset", $ Input Name. $------------------------------------------------------------ 0, $ Reference (which "Param-section" is related with) 1, $ Value 0x00A, $ Descriptor "", $ Icon file "Manual Reset"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info19_1 = $ this field defines the Output1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\output.ico", $ Icon file "Output Enable"; $ Input Name. $ ==================================================================================== FunctionBlock20 = $ "Pulse Generator" 1, $ Revision "Pulse Generator", $ FunctionBlock Name 2, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 12, $ sfb_ID 0, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0841, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 1, $ Max Input number (input 1,2 and reset input) 1, $ Max Output number (includes "/Fault Present") 1, $ Min Input number 1, $ Min Output number 1, $ Default Input number (Reset, Input1) 1, $ Default Output number (Output1) "FBICON\\PulseGenerator.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\PulseGenerator.htm", $ Help file for specified FunctionBlock 25, $ Min. execution time (ms): this value is assumption. 25, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 1, $ Display Attribute 0, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ------------------------------------------------------------------------------- Param20_1= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_SETTABLE_PATH) 0xC7, $ data type=UINT 2, $ data size=2byte "On Pulse time", $ name "ms", $ unit "", $ Help string 1,300,50, $ min/ max/ default (0~300s (=300,000ms = 0x7530ms) 10,1,1,1, $ mult/ div /base/ offset scaling 10,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places/ offset links not us 0,16,1; $ offset/ usebit/ ConfigNumber $ ------------------------------------------------------------------------------- Param20_2= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_SETTABLE_PATH) 0xC7, $ data type=UINT 2, $ data size=2byte "Off Pulse time", $ name "ms", $ unit "", $ Help string 1,300,50, $ min/ max/ default (0~300s (=300,000ms = 0x7530ms) 10,1,1,1, $ mult/ div /base/ offset scaling 10,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places/ offset links not us 0,16,2; $ offset/ usebit/ ConfigNumber $ ---------------------------------------------------------------------------------- Input_Info20_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\input.ico", $ Icon file. "Input"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info20_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\output.ico", $ Icon file. "Output Enable"; $ Input Name. $------------------------------------------------------------ $ ==================================================================================== FunctionBlock21 = $ "RS-FF" 1, $ Revision "RS-FF", $ FunctionBlock Name 1, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 11, $ sfb_ID 0, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0841, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 2, $ Max Input number (input 1,2 and reset input) 1, $ Max Output number (includes "/Fault Present") 2, $ Min Input number 1, $ Min Output number 2, $ Default Input number (Reset, Input1) 1, $ Default Output number (Output1) "FBICON\\RS-FF.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\RS-FF.htm", $ Help file for specified FunctionBlock 18, $ Min. execution time (ms): this value is assumption. 18, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 1, $ Display Attribute 1, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ------------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Input_Info21_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\input.ico", $ Icon file. "Input"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info21_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\RE.ico", $ Icon file. "Reset"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info21_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\output.ico", $ Icon file. "Output Enable"; $ Input Name. $------------------------------------------------------------ $ ==================================================================================== FunctionBlock22 = $ "Enable Switch" 1, $ Revision "Enable Switch", $ FunctionBlock Name 3, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 13, $ sfb_ID 0, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0841, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 4, $ Max Input number (input 1,2 and reset input) 4, $ Max Output number (includes "/Fault Present") 2, $ Min Input number 4, $ Min Output number 2, $ Default Input number (Reset, Input1) 4, $ Default Output number (Output1) "FBICON\\EnableSwitch.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\EnableSwitch.htm", $ Help file for specified FunctionBlock 51, $ Min. execution time (ms): this value is assumption. 51, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 1, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------- Param22_1= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Reset Condition", $ name "", $ unit "", $ Help string 1,1,1, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places$ 0,1,0; $ offset/ usebit/ ConfigNumber EnumPar22_1= 1,"Auto Reset"; Param22_2= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Input Type", $ name "", $ unit "", $ Help string 0,1,1, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 4,2,0; $ offset/ usebit/ ConfigNumber EnumPar22_2= 0,"Single Channel", 1,"Dual Channel Equivalent"; $ ------------------------------------------------------------------------------- Param22_3= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_SETTABLE_PATH) 0xC7, $ data type=UINT 2, $ data size=2byte "Discrepancy Time", $ name "ms", $ unit "", $ Help string 0,0xBB8,0x03, $ min/ max/ default 10,1,1,1, $ mult/ div /base/ offset scaling 10,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places 0,16,1; $ offset/ usebit/ ConfigNumber $ ---------------------------------------------------------------------------------- Input_Info22_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value (In this case, it means "Reset") 0x04A, $ Descriptor (In this case, it means "Required"+"Single") "FBICON\\NO.ico", $ Icon file "Input1 (NO)", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x0A2, $ Descriptor "FBICON\\NO.ico", $ Icon file "Input1 (NO)", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x092, $ Descriptor "FBICON\\NO.ico", $ Icon file "Input1 (NO)"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info22_2 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input2 (NC)", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x052, $ Descriptor "FBICON\\NO.ico", $ Icon file "Input2 (NO)", $ Input Name $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x062, $ Descriptor "FBICON\\NC.ico", $ Icon file "Input2 (NC)"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info22_3 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "FBICON\\input.ico", $ Icon file. "Grip Input", $ Input Name. $------------------------------------------------------------ 1, $ Reference (which "Param-section" is related with) 1, $ Value 0x001, $ Descriptor "FBICON\\input.ico", $ Icon file. "Grip Input", $ Input Name. $------------------------------------------------------------ 1, $ Reference (which "Param-section" is related with) 2, $ Value 0x001, $ Descriptor "FBICON\\input.ico", $ Icon file. "Grip Input"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info22_4 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 1, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "FBICON\\input.ico", $ Icon file. "Release Input", $ Input Name. $------------------------------------------------------------ 1, $ Reference (which "Param-section" is related with) 1, $ Value 0x001, $ Descriptor "FBICON\\input.ico", $ Icon file. "Release Input", $ Input Name. $------------------------------------------------------------ 1, $ Reference (which "Param-section" is related with) 2, $ Value 0x001, $ Descriptor "FBICON\\input.ico", $ Icon file. "Release Input"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info22_1 = $ this field defines the Output1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\output.ico", $ Icon file "Output Enable"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info22_2 = $ this field defines the Output1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x009, $ Descriptor "FBICON\\output.ico", $ Icon file "Grip Enable"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info22_3 = $ this field defines the Output1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x009, $ Descriptor "FBICON\\output.ico", $ Icon file "Release Enable"; $ Input Name. $ ---------------------------------------------------------------------------------- Output_Info22_4 = $ this field defines the Output1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x009, $ Descriptor "FBICON\\error.ico", $ Icon file "Discrepancy Error"; $ Input Name. $ ==================================================================================== FunctionBlock23 = $ "Muting" 1, $ Revision "Muting", $ FunctionBlock Name 3, $ Type (Logic:1 / Timer:2 / Device:3 / Reset:4/ Connector:5) 14, $ sfb_ID 0, $ sfun_ID 0, $ ex_sfb_ID 0, $ ex_sfun_ID 0, $ Event_ID (at this moment, this is fixed value) 0x0841, $ Control/Status Register 0, $ Interval time (at this moment, this is fixed value) 8, $ Max Input number (input 1,2 and reset input) 7, $ Max Output number (includes "/Fault Present") 8, $ Min Input number 2, $ Min Output number 8, $ Default Input number (Reset, Input1) 2, $ Default Output number (Output1) "FBICON\\Muting.ico", $ Icon file "HELP\\FunctionBlockHelp.chm::_RESOURCE\\Muting.htm", $ Help file for specified FunctionBlock 120, $ Min. execution time (ms): this value is assumption. 120, $ Worst execution time (ms): this value is assumption. 0, $ Syncro 0, $ Display Attribute 1, $ Use FaultPresent (0: not use/ 1: use) 0; $ Monitor FunctionBlock Internal Data $ ------------------------------------------------------------------------------- Param23_1= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Reset Condition", $ name "", $ unit "", $ Help string 1,1,1, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 0,1,0; $ offset/ usebit/ ConfigNumber EnumPar23_1= 1,"Auto Reset"; $ ------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------- Param23_2= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Muting Mode" , $ name "", $ unit "", $ Help string 0,3,1, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 4,2,0; $ offset/ usebit/ ConfigNumber EnumPar23_2= 0,"Position Detection", 1,"Parallel Muting with 2 Sensors", 2,"Sequential Muting(Forward Direction)", 3,"Sequential Muting(Both Directions)"; $ ------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------- Param23_3= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte $ name "Syncronization Time", "ms", $ unit "", $ Help string 3,300,300, $ min/ max/ default 10,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places 0,16,3; $ offset/ usebit/ ConfigNumber $ ------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------- Param23_4= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Input Type of AOPD", $ name "", $ unit "", $ Help string 1,2,1, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 6,2,0; $ offset/ usebit/ ConfigNumber EnumPar23_4= 1,"Dual Channel Equivalent", 2,"Dual Channel Complementary"; $ ------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------- Param23_5= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC6, $ data type=UINT 1, $ data size=1byte "Discrepancy Time (AOPD)", $ name "ms", $ unit "", $ Help string 0,50,3, $ min/ max/ default 10,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places 0,8,1; $ offset/ usebit/ ConfigNumber $ ------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------- Param23_6= 0, $ shall Equal 0 , $ path size "", $ path 0x0002, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC7, $ data type=UINT 2, $ data size=2byte "Input Type of Override Signal", $ name "", $ unit "", $ Help string 0,3,3, $ min/ max/ default 1,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,0, $ mult/ div /base/ offset links not used 0, $ decimal places 8,2,0; $ offset/ usebit/ ConfigNumber EnumPar23_6= 0,"Single Channel", 1,"Dual Channel Equivalent", 2,"Dual Channel Complementary", 3,"Not Used"; $ ------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------- Param23_7= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC6, $ data type=UINT 1, $ data size=1byte "Discrepancy Time (Override)", $ name "ms", $ unit "", $ Help string 0,50,3, $ min/ max/ default 10,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places 8,8,1; $ offset/ usebit/ ConfigNumber $ ------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------- Param23_8= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC6, $ data type=UINT 1, $ data size=1byte "Max Muting Time", $ name "ms", $ unit "", $ Help string 0,255,120, $ min/ max/ default 500,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places 8,8,2; $ offset/ usebit/ ConfigNumber $ ------------------------------------------------------------------------------- $ ------------------------------------------------------------------------------- Param23_9= 0, $ shall Equal 0 , $ path size "", $ path 0x0004, $ descriptor(SUPPORT_ENUMERATED_STRING) 0xC6, $ data type=UINT 1, $ data size=1byte "Max Override Time", $ name "ms", $ unit "", $ Help string 1,255,120, $ min/ max/ default 500,1,1,0, $ mult/ div /base/ offset scaling 0,0,0,1, $ mult/ div /base/ offset links not used 0, $ decimal places 0,8,2; $ offset/ usebit/ ConfigNumber $ ------------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Input_Info23_1 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 4, $ Reference (which "Param-section" is related with) 0, $ Value 0x04A, $ Descriptor "FBICON\\NC.ico", $ Icon file "AOPD Input(NC)", $ Input Name. $------------------------------------------------------------ 4, $ Reference (which "Param-section" is related with) 1, $ Value 0x0A2, $ Descriptor "FBICON\\NC.ico", $ Icon file "AOPD Input1 (NC)", $ Input Name $------------------------------------------------------------ 4, $ Reference (which "Param-section" is related with) 2, $ Value 0x092, $ Descriptor "FBICON\\NC.ico", $ Icon file "AOPD Input1 (NC)"; $ Input Name $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info23_2 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 4, $ Reference (which "Param-section" is related with) 0, $ Value 0x52, $ Descriptor "FBICON\\NC.ico", $ Icon file "AOPD Input2 (NC)", $ Input Name $------------------------------------------------------------ 4, $ Reference (which "Param-section" is related with) 1, $ Value 0x52, $ Descriptor "FBICON\\NC.ico", $ Icon file "AOPD Input2 (NC)", $ Input Name $------------------------------------------------------------ 4, $ Reference (which "Param-section" is related with) 2, $ Value 0x62, $ Descriptor "FBICON\\NO.ico", $ Icon file "AOPD Input2 (NO)"; $ Input Name $----------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Input_Info23_3 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 6, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\NO.ico", $ Icon file "Override Input", $ Input Name. $------------------------------------------------------------ 6, $ Reference (which "Param-section" is related with) 1, $ Value 0x112, $ Descriptor "FBICON\\NO.ico", $ Icon file "Override Input1 (NO)", $ Input Name $------------------------------------------------------------ 6, $ Reference (which "Param-section" is related with) 2, $ Value 0x122, $ Descriptor "FBICON\\NO.ico", $ Icon file "Override Input1 (NO)", $ Input Name $------------------------------------------------------------ 6, $ Reference (which "Param-section" is related with) 3, $ Value 0x004, $ Descriptor "FBICON\\NO.ico", $ Icon file "Override Input"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info23_4 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 6, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "", $ Icon file "", $ Input Name. $------------------------------------------------------------ 6, $ Reference (which "Param-section" is related with) 1, $ Value 0x0E2, $ Descriptor "FBICON\\NO.ico", $ Icon file "Override Input2 (NO)", $ Input Name $------------------------------------------------------------ 6, $ Reference (which "Param-section" is related with) 2, $ Value 0x0D2, $ Descriptor "FBICON\\NC.ico", $ Icon file. "Override Input2 (NC)", $ Input Name. $------------------------------------------------------------ 6, $ Reference (which "Param-section" is related with) 3, $ Value 0x004, $ Descriptor "", $ Icon file ""; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info23_5 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\S11.ico", $ Icon file "Muting Signal 11", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x00A, $ Descriptor "FBICON\\S11.ico", $ Icon file "Muting Signal 11", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x00A, $ Descriptor "FBICON\\S11.ico", $ Icon file "Muting Signal 11", $ Input Name. $------------------------------------------------------------ 2, $ Reference (which "Param-section" is related with) 3, $ Value 0x00A, $ Descriptor "FBICON\\S11.ico", $ Icon file "Muting Signal 11"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Input_Info23_6 = $ this field defines the Input2 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "FBICON\\S12.ico", $ Icon file "Muting Signal 12", $ Input Name. $------------------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x00A, $ Descriptor "FBICON\\S12.ico", $ Icon file "Muting Signal 12", $ Input Name. $------------------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x00A, $ Descriptor "FBICON\\S12.ico", $ Icon file "Muting Signal 12", $ Input Name. $------------------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 3, $ Value 0x00A, $ Descriptor "FBICON\\S12.ico", $ Icon file "Muting Signal 12"; $ Input Name. $------------------------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Input_Info23_7 = $ this field defines the Input7 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "FBICON\\S21.ico", $ Icon file "Muting Signal 21", $ Input Name. $------------------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x004, $ Descriptor "FBICON\\S21.ico", $ Icon file "Muting Signal 21", $ Input Name. $------------------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x00A, $ Descriptor "FBICON\\S21.ico", $ Icon file "Muting Signal 21", $ Input Name. $------------------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 3, $ Value 0x00A, $ Descriptor "FBICON\\S21.ico", $ Icon file "Muting Signal 21"; $ Input Name. $------------------------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Input_Info23_8 = $ this field defines the Input8 configuration. $ ---------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 0, $ Value 0x004, $ Descriptor "FBICON\\S22.ico", $ Icon file "Muting Signal 22", $ Input Name. $------------------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 1, $ Value 0x004, $ Descriptor "FBICON\\S22.ico", $ Icon file "Muting Signal 22", $ Input Name. $------------------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 2, $ Value 0x00A, $ Descriptor "FBICON\\S22.ico", $ Icon file "Muting Signal 22", $ Input Name. $------------------------------------------------------------------------------------------- 2, $ Reference (which "Param-section" is related with) 3, $ Value 0x00A, $ Descriptor "FBICON\\S22.ico", $ Icon file "Muting Signal 22"; $ Input Name. $------------------------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Output_Info23_1 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\output.ico", $ Icon file. "Output Enable"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info23_2 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x00A, $ Descriptor "FBICON\\testout.ico", $ Icon file. "Muting Status"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info23_3 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "FBICON\\testout.ico", $ Icon file. "Override Status"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info23_4 = $ this field defines the Input1 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "FBICON\\error.ico", $ Icon file. "Sequence Error"; $ Input Name. $------------------------------------------------------------ $ ------------------------------------------------------------------------------------ Output_Info23_5 = $ this field defines the Input1 configuration. $ ------------------------------------------------------------------------------------ 0, $ Reference 0, $ Value 0x001, $ Descriptor "FBICON\\error.ico", $ Icon file. "Synchronization Error"; $ Input Name. $------------------------------------------------------------------------------- $ ---------------------------------------------------------------------------------- Output_Info23_6 = $ this field defines the Output6 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "FBICON\\error.ico", $ Icon file. "Discrepancy Error (AOPD)"; $ Input Name. $------------------------------------------------------------ $ ---------------------------------------------------------------------------------- Output_Info23_7 = $ this field defines the Output7 configuration. $ ---------------------------------------------------------------------------------- 0, $ Reference (which "Param-section" is related with) 0, $ Value 0x001, $ Descriptor "FBICON\\error.ico", $ Icon file. "Discrepancy Error (Override)"; $ Input Name. $------------------------------------------------------------