$ EZ-EDS Version 3.27.1.20191218 Generated Electronic Data Sheet $ DeviceNet Electronic Data Sheet $ Electronic Data Sheet generated using SST EDS Editor $ Copyright (C) 1998 S-S Technologies Inc. [File] DescText = "STEC Digital Mass-Frow-Controller EDS File"; CreateDate = 07-16-2009; CreateTime = 16:20:00; ModDate = 07-16-2009; ModTime = 16:20:00; Revision = 1.0; [Device] VendCode = 162; VendName = "HORIBA STEC Co., Ltd."; ProdType = 26; ProdTypeStr = "MASS FLOW DEVICE"; ProdCode = 25; MajRev = 1; MinRev = 1; ProdName = "SEC-N104"; Catalog = "N/A"; [IO_Info] Default = 0x0001; PollInfo = 0x0001, 2, 1; Input1 = 2, 0, 0x0001, "Flow", 6, "20 04 24 01 30 03", "Flow"; Input2 = 3, 0, 0x0001, "Status,Flow", 6, "20 04 24 02 30 03", "STEC's Default Input."; Input3 = 5, 0, 0x0001, "Status,Flow,Valve", 6, "20 04 24 03 30 03", "Status,Flow,Valve"; Input4 = 5, 0, 0x0001, "Status,Flow,Setpoint", 6, "20 04 24 04 30 03", "Status,Flow,Setpoint"; Input5 = 7, 0, 0x0001, "Status,Flow,Setpoint,Valve", 6, "20 04 24 05 30 03", "Status,Flow,Setpoint,Valve"; Input6 = 8, 0, 0x0001, "Stat,Flow,Set,Override,Valve", 6, "20 04 24 06 30 03", "Status,Flow,Setpoint,Override,Valve"; Input7 = 1, 0, 0x0001, "Status", 6, "20 04 24 09 30 03", "Status"; Input8 = 8, 0, 0x0001, "Exception Detail Alarm", 6, "20 04 24 0A 30 03", "Exception Detail Alarm"; Input9 = 8, 0, 0x0001, "Exception Detail Warning", 6, "20 04 24 0B 30 03", "Exception Detail Warning"; Input10 = 15, 0, 0x0001, "Exception Detail Alarm / Warning", 6, "20 04 24 0C 30 03", "Exception Detail Alarm and Warning"; Input11 = 4, 0, 0x0001, "Flow(FP)", 6, "20 04 24 0D 30 03", "FP-Flow"; Input12 = 5, 0, 0x0001, "Status,Flow(FP)", 6, "20 04 24 0E 30 03", "Status,FP-Flow"; Input13 = 9, 0, 0x0001, "Status,Flow,Valve(FP)", 6, "20 04 24 0F 30 03", "Status,FP-Flow,FP-Valve"; Input14 = 9, 0, 0x0001, "Status,Flow,Setpoint(FP)", 6, "20 04 24 10 30 03", "Status,FP-Flow,FP-Setpoint"; Input15 = 13, 0, 0x0001, "Status,Flow,Setpoint,Valve(FP)", 6, "20 04 24 11 30 03", "Status,FP-Flow,FP-Setpoint,FP-Valve"; Input16 = 14, 0, 0x0001, "Stat,Flow,Set,Override,Valve(FP)", 6, "20 04 24 12 30 03", "Status,FP-Flow,FP-Setpoint,Override,FP-Valve"; Output1 = 2, 0, 0x0001, "Setpoint", 6, "20 04 24 07 30 03", "STEC's Default Output."; Output2 = 3, 0, 0x0001, "Override,Setpoint", 6, "20 04 24 08 30 03", "Override,Setpoint"; Output3 = 4, 0, 0x0001, "FP-Setpoint", 6, "20 04 24 13 30 03", "FP-Setpoint"; Output4 = 5, 0, 0x0001, "Override,Setpoint(FP)", 6, "20 04 24 14 30 03", "Override,FP-Setpoint";