$ DeviceNet Electronic Data Sheet [File] DescText= "CDN455 MATIC"; CreateDate= 02-07-2003; CreateTime= 01:00:00; ModDate= 06-13-2003; ModTime= 01:00:00; Revision= 1.14; [Device] VendCode= 129; ProdType= 100; ProdCode= 3; MajRev= 1; MinRev= 14; VendName= "AUMA Actuators Inc."; ProdTypeStr="General Purpose Discrete I/O"; ProdName= "CDN455 MATIC"; Catalog= "AUMA Actuator CDN455 MATIC"; [IO_Info] Default= 0x0001; PollInfo= 0x0001,1,1; Input1= 4,0,0x0001,"Input 1",6,"20 04 24 01 30 03","Basic"; Output1= 4,0,0x0001,"Output 1",6,"20 04 24 02 30 03","Default"; [Params] $ Enumerated Parameters Param1= 0, $ parameter value slot 6, "20 66 24 01 30 03", $ link size and path 0x03, $ descriptor 0xC1, 1, $ data type, length "Open cmd.", $ parameter name "", $ units string "", $ Help string 0,1,0, 1,1,1,0,0,0,0,0,0; Param2= 0, $ parameter value slot 6, "20 66 24 02 30 03", $ link size and path 0x03, $ descriptor 0xC1, 1, $ data type, length "Close cmd.", $ parameter name "", $ units string "", $ Help string 0,1,0, 1,1,1,0,0,0,0,0,0; Param3= 0, $ parameter value slot 6, "20 66 24 03 30 03", $ link size and path 0x03, $ descriptor 0xC1, 1, $ data type, length "Relay 0", $ parameter name "", $ units string "", $ Help string 0,1,0, 1,1,1,0,0,0,0,0,0; Param4= 0, $ parameter value slot 6, "20 66 24 04 30 03", $ link size and path 0x03, $ descriptor 0xC1, 1, $ data type, length "Relay 1", $ parameter name "", $ units string "", $ Help string 0,1,0, 1,1,1,0,0,0,0,0,0; Param5= 0, $ parameter value slot 6, "20 66 24 05 30 03", $ link size and path 0x03, $ descriptor 0xC1, 1, $ data type, length "Enable Setpoint", $ parameter name "", $ units string "", $ Help string 0,1,0, 1,1,1,0,0,0,0,0,0; Param6= 0, $ parameter value slot 6, "20 66 24 10 30 03", $ link size and path 0x03, $ descriptor 0xC1, 1, $ data type, length "ESD", $ parameter name "", $ units string "Emergancy shut down", $ Help string 0,1,0, 1,1,1,0,0,0,0,0,0; Param7= 0, $ parameter value slot 6, "20 65 24 01 30 03", $ link size and path 0x32, $ descriptor 0xC1, 1, $ data type, length "Close torque active", $ parameter name "", $ units string "", $ Help string 0,1,0, 1,1,1,0,0,0,0,0,0; Param8= 0, $ parameter value slot 6, "20 65 24 02 30 03", $ link size and path 0x32, $ descriptor 0xC1, 1, $ data type, length "Open torque active", $ parameter name "", $ units string "", $ Help string 0,1,0, 1,1,1,0,0,0,0,0,0; Param9= 0, $ parameter value slot 6, "20 65 24 03 30 03", $ link size and path 0x32, $ descriptor 0xC1, 1, $ data type, length "Close limit active", $ parameter name "", $ units string "", $ Help string 0,1,0, 1,1,1,0,0,0,0,0,0; Param10= 0, $ parameter value slot 6, "20 65 24 04 30 03", $ link size and path 0x32, $ descriptor 0xC1, 1, $ data type, length "Open limit active", $ parameter name "", $ units string "", $ Help string 0,1,0, 1,1,1,0,0,0,0,0,0; Param11= 0, $ parameter value slot 6, "20 65 24 05 30 03", $ link size and path 0x32, $ descriptor 0xC1, 1, $ data type, length "Phase image", $ parameter name "", $ units string "", $ Help string 0,1,0, 1,1,1,0,0,0,0,0,0; Param12= 0, $ parameter value slot 6, "20 65 24 06 30 03", $ link size and path 0x32, $ descriptor 0xC1, 1, $ data type, length "Thermostat Image", $ parameter name "", $ units string "", $ Help string 0,1,0, 1,1,1,0,0,0,0,0,0; Param13= 0, $ parameter value slot 6, "20 65 24 07 30 03", $ link size and path 0x32, $ descriptor 0xC1, 1, $ data type, length "Selector switch remote", $ parameter name "", $ units string "", $ Help string 0,1,0, 1,1,1,0,0,0,0,0,0; Param14= 0, $ parameter value slot 6, "20 65 24 08 30 03", $ link size and path 0x32, $ descriptor 0xC1, 1, $ data type, length "Selector Switch local", $ parameter name "", $ units string "", $ Help string 0,1,0, 1,1,1,0,0,0,0,0,0; $ non enumerated parameters Param15= 0, $ parameter value slot 6, "20 64 24 01 30 02", $ link size and path 0x30, $ descriptor 0xC7, 2, $ data type, length "Status Word", $ parameter name "", $ units string "", 0,65535,0, 1,1,1,0,0,0,0,0,0; Param16= 0, $ parameter value slot 6, "20 64 24 01 30 0A", $ link size and path 0x30, $ descriptor 0xC7, 2, $ data type, length "Extended Status", $ parameter name "", $ units string "", 0,65535,0, 1,1,1,0,0,0,0,0,0; Param17= 0, $ parameter value slot 6, "20 64 24 01 30 05", $ link size and path 0x30, $ descriptor 0xC7, 2, $ data type, length "Position", $ parameter name "", $ units string "", 0,1000,0, 1,1,1,0,0,0,0,0,0; Param18= 0, $ parameter value slot 6, "20 64 24 01 30 04", $ link size and path 0x30, $ descriptor 0xC3, 2, $ data type, length "Analog Input 1", $ parameter name "", $ units string "", 0,1000,0, 1,1,1,0,0,0,0,0,0; Param19= 0, $ parameter value slot 6, "20 64 24 01 30 06", $ link size and path 0x30, $ descriptor 0xC3, 2, $ data type, length "Analog Input 2", $ parameter name "", $ units string "", 0,1000,0, 1,1,1,0,0,0,0,0,0; Param20= 0, $ parameter value slot 6, "20 64 24 01 30 09", $ link size and path 0x30, $ descriptor 0xC3, 2, $ data type, length "Deadband", $ parameter name "", $ units string "", 0,1000,0, 1,1,1,0,0,0,0,0,0; Param21= 0, $ parameter value slot 6, "20 64 24 01 30 0B", $ link size and path 0x30, $ descriptor 0xC3, 2, $ data type, length "Reserved", $ parameter name "", $ units string "", 0,1000,0, 1,1,1,0,0,0,0,0,0; Param22= 0, $ parameter value slot 6, "20 64 24 01 30 0C", $ link size and path 0x30, $ descriptor 0xC3, 2, $ data type, length "Reserved", $ parameter name "", $ units string "", 0,1000,0, 1,1,1,0,0,0,0,0,0; Param23= 0, $ parameter value slot 6, "20 64 24 01 30 0D", $ link size and path 0x30, $ descriptor 0xC8, 4, $ data type, length "#Motor starts", $ parameter name "", $ units string "", 0,0,0, 1,1,1,0,0,0,0,0,0; Param24= 0, $ parameter value slot 6, "20 64 24 01 30 0E", $ link size and path 0x30, $ descriptor 0xC8, 4, $ data type, length "#Cycles", $ parameter name "", $ units string "", 0,0,0, 1,1,1,0,0,0,0,0,0; Param25= 0, $ parameter value slot 6, "20 64 24 01 30 0F", $ link size and path 0x30, $ descriptor 0xC8, 4, $ data type, length "#Starts exceeded", $ parameter name "", $ units string "", 0,0,0, 1,1,1,0,0,0,0,0,0; Param26= 0, $ parameter value slot 6, "20 64 24 01 30 10", $ link size and path 0x30, $ descriptor 0xC8, 4, $ data type, length "#Thermostat trip", $ parameter name "", $ units string "", 0,0,0, 1,1,1,0,0,0,0,0,0; Param27= 0, $ parameter value slot 6, "20 64 24 01 30 11", $ link size and path 0x30, $ descriptor 0xC8, 4, $ data type, length "#Limit trip", $ parameter name "", $ units string "", 0,0,0, 1,1,1,0,0,0,0,0,0; Param28= 0, $ parameter value slot 6, "20 64 24 01 30 12", $ link size and path 0x30, $ descriptor 0xC8, 4, $ data type, length "#Torque trip", $ parameter name "", $ units string "", 0,0,0, 1,1,1,0,0,0,0,0,0; Param29= 0, $ parameter value slot 6, "20 64 24 01 30 13", $ link size and path 0x30, $ descriptor 0xC8, 4, $ data type, length "#Running minutes", $ parameter name "", $ units string "", 0,0,0, 1,1,1,0,0,0,0,0,0; Param30= 0, $ parameter value slot 6, "20 64 24 01 30 14", $ link size and path 0x30, $ descriptor 0xC8, 4, $ data type, length "#Running seconds", $ parameter name "", $ units string "", 0,0,0, 1,1,1,0,0,0,0,0,0; Param31= 0, $ parameter value slot 6, "20 64 24 01 30 3B", $ link size and path 0x30, $ descriptor 0xC7, 2, $ data type, length "#Starts per hour", $ parameter name "", $ units string "", 0,0,0, 1,1,1,0,0,0,0,0,0; Param32= 0, $ parameter value slot 6, "20 64 24 01 30 01", $ link size and path 0x01, $ descriptor 0xC7, 2, $ data type, length "CommandWord", $ parameter name "", $ units string "", 0,65535,0, 1,1,1,0,0,0,0,0,0; Param33= 0, $ parameter value slot 6, "20 64 24 01 30 03", $ link size and path 0x01, $ descriptor 0xC7, 2, $ data type, length "Setpoint", $ parameter name "", $ units string "", 0,1000,0, 1,1,1,0,0,0,0,0,0; Param34= 0, $ parameter value slot 6, "20 64 24 01 30 15", $ link size and path 0x01, $ descriptor 0xC7, 2, $ data type, length "ControlWord", $ parameter name "", $ units string "", 0,65535,0, 1,1,1,0,0,0,0,0,0; Param35= 0, $ parameter value slot 6, "20 64 24 01 30 16", $ link size and path 0x01, $ descriptor 0xC7, 2, $ data type, length "InstRevTime", $ parameter name "", $ units string "Motor Direction change delay in 100ms resloution", 0,1000,5, 1,1,1,0,0,0,0,0,0; Param36= 0, $ parameter value slot 6, "20 64 24 01 30 1F", $ link size and path 0x01, $ descriptor 0xC7, 2, $ data type, length "Adc0Lo", $ parameter name "", $ units string "", 0,65535,0, 1,1,1,0,0,0,0,0,0; Param37= 0, $ parameter value slot 6, "20 64 24 01 30 20", $ link size and path 0x01, $ descriptor 0xC7, 2, $ data type, length "Adc0Hi", $ parameter name "", $ units string "", 0,32767,32767, 1,1,1,0,0,0,0,0,0; Param38= 0, $ parameter value slot 6, "20 64 24 01 30 21", $ link size and path 0x01, $ descriptor 0xC7, 2, $ data type, length "Adc0Scale", $ parameter name "", $ units string "", 0,4095,1000, 1,1,1,0,0,0,0,0,0; Param39= 0, $ parameter value slot 6, "20 64 24 01 30 22", $ link size and path 0x01, $ descriptor 0xC7, 2, $ data type, length "Adc1Lo", $ parameter name "", $ units string "", 0,65535,0, 1,1,1,0,0,0,0,0,0; Param40= 0, $ parameter value slot 6, "20 64 24 01 30 23", $ link size and path 0x01, $ descriptor 0xC7, 2, $ data type, length "Adc1Hi", $ parameter name "", $ units string "", 0,32767,32767, 1,1,1,0,0,0,0,0,0; Param41= 0, $ parameter value slot 6, "20 64 24 01 30 24", $ link size and path 0x01, $ descriptor 0xC7, 2, $ data type, length "Adc1Scale", $ parameter name "", $ units string "", 0,4095,1000, 1,1,1,0,0,0,0,0,0; Param42= 0, $ parameter value slot 6, "20 64 24 01 30 25", $ link size and path 0x01, $ descriptor 0xC7, 2, $ data type, length "Adc2Lo", $ parameter name "", $ units string "", 0,4095,0, 1,1,1,0,0,0,0,0,0; Param43= 0, $ parameter value slot 6, "20 64 24 01 30 26", $ link size and path 0x01, $ descriptor 0xC7, 2, $ data type, length "Adc2Hi", $ parameter name "", $ units string "", 0,32767,32767, 1,1,1,0,0,0,0,0,0; Param44= 0, $ parameter value slot 6, "20 64 24 01 30 27", $ link size and path 0x01, $ descriptor 0xC7, 2, $ data type, length "Adc2Scale", $ parameter name "", $ units string "", 0,4095,1000, 1,1,1,0,0,0,0,0,0; Param45= 0, $ parameter value slot 6, "20 64 24 01 30 2d", $ link size and path 0x01, $ descriptor 0xC7, 2, $ data type, length "Fail Position", $ parameter name "", $ units string "", 0,65535,0, 1,1,1,0,0,0,0,0,0; [ParamClass] MaxInst=33; Descriptor=9; CfgAssembly=0; [EnumPar] Param1= "No action", "Open cmd."; Param2= "No action", "Close cmd."; Param3= "Off", "On"; Param4= "Off", "On"; Param5= "Off", "On"; Param6= "Off", "On"; Param7= "No", "Yes"; Param8= "No", "Yes"; Param9= "No", "Yes"; Param10="No", "Yes"; Param11="Yes", "No"; Param12="Yes", "No"; Param13="No", "Remote"; Param14="No", "Local"; [Groups]