$ EZ-EDS Version 1.2 Generated Electronic Data Sheet $ EDS-File for Cube67 Ethernet/IP Busnode [File] DescText = "EDS for CUBE20 BN EIP"; CreateDate = 12-19-2008; CreateTime = 09:11:25; ModDate = 07-05-2010; ModTime = 16:25:30; Revision = 1.1; HomeURL = "http://www.murrelektronik.com"; [Device] VendCode = 640; VendName = "Murrelektronik GmbH"; ProdType = 12; ProdTypeStr = "Communication Adapter"; ProdCode = 56005; MajRev = 1; MinRev = 1; ProdName = "Cube20 BN-E/IP"; Catalog = "56005"; Icon = "CUBE20_BN_E.ico"; [Device Classification] Class1 = EtherNetIP; [Params] Param1 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Input Size", $ name "Bytes", $ units "This parameter sets the input size", $ help string 16,500,56, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param2 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Output Size", $ name "Bytes", $ units "This parameter sets the output size", $ help string 16,496,16, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param3 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC2, $ Data Type 1, $ Data Size in bytes "Configuartion Size", $ name "Bytes", $ units "Allways Zero", $ help string 0,0,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places [Connection Manager] Connection1 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = transport type: listen-only $ 25 = transport type: input-only $ 26 = transport type: exclusive-owner $ 27 = transport type: redundant-owner $ 28-30 = reserved $ 31 = Client = 0 / Server = 1 0x4424440A, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,Param1,, $ O->T RPI, size, format ,Param2,, $ T->O RPI, size, format ,, $ config #1 size, format ,, $ config #2 size, format "I/O Connection", $ Connection Name "", $ help string "20 04 24 06 2C 70 2C 64"; $ Path; dummy path, must be modified to correct settings